A vulnerability has been identified in APOGEE MBC (PPC) (BACnet) (All versions), APOGEE MBC (PPC) (P2 Ethernet) (All versions), APOGEE MEC (PPC) (BACnet) (All versions), APOGEE MEC (PPC) (P2 Ethernet) (All versions), APOGEE PXC Compact (BACnet) (All versions < V3.5.4), APOGEE PXC Compact (P2 Ethernet) (All versions < V2.8.19), APOGEE PXC Modular (BACnet) (All versions < V3.5.4), APOGEE PXC Modular (P2 Ethernet) (All versions < V2.8.19), Desigo PXC00-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC00-U (All versions >= V2.3 and < V6.30.016), Desigo PXC001-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC100-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC12-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC128-U (All versions >= V2.3 and < V6.30.016), Desigo PXC200-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC22-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC22.1-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC36.1-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC50-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC64-U (All versions >= V2.3 and < V6.30.016), Desigo PXM20-E (All versions >= V2.3 and < V6.30.016), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions < V2017.02.4), Nucleus Source Code (All versions), TALON TC Compact (BACnet) (All versions < V3.5.4), TALON TC Modular (BACnet) (All versions < V3.5.4). FTP server does not properly validate the length of the “USER” command, leading to stack-based buffer overflows. This may result in Denial-of-Service conditions and Remote Code Execution. (FSMD-2021-0010)
Affected vendor
Siemens
Affected product
Nucleus Net
CVSS vector
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Weakness type (CWE)
Published
2021-11-09

Risk analysis

Based on its CVSS vector, this vulnerability is exploitable over the network, low attack complexity, requiring no privileges, no user interaction. Successful exploitation leads to high impact to confidentiality, high impact to integrity, high impact to availability.

Its EPSS score of 3.0% reflects a lower probability of exploitation activity in the wild over the next 30 days, placing it above 86% of all scored CVEs.

Check your external exposure to CVE-2021-31886

  • Confirm whether Siemens Nucleus Net is running on any internet-facing host or subdomain.
  • Match discovered service fingerprints against the version affected by CVE-2021-31886.
  • Prioritise remediation if the asset is public, business-critical, or near authentication/payment flows.

How ThreatPort helps with CVE-2021-31886

ThreatPort's external attack surface scanner checks your internet-facing assets — agentlessly, from the outside in — for the exposed services and versions that CVE-2021-31886 affects, then prioritises the finding by real risk using CISA KEV and FIRST.org EPSS.

Run a free external exposure scan

Are you exposed to CVE-2021-31886?

Run an instant, non-intrusive external scan to check your attack surface for CVE-2021-31886.

Start free scan

No credit card. Agentless.