MEDIUM SEVERITY

CVE-2011-4532

Automation License Manager vulnerability

CVSS
5.0
EPSS
3.6%
EPSS pct
88th
Exploited
No known
Absolute path traversal vulnerability in the ALMListView.ALMListCtrl ActiveX control in almaxcx.dll in the graphical user interface in Siemens Automation License Manager (ALM) 2.0 through 5.1+SP1+Upd2 allows remote attackers to overwrite arbitrary files via the Save method.
Affected vendor
Siemens
Affected product
Automation License Manager
CVSS vector
AV:N/AC:L/Au:N/C:N/I:P/A:N
Weakness type (CWE)
Published
2012-01-08

Risk analysis

Based on its CVSS vector, this vulnerability is exploitable over the network, low attack complexity, requiring no authentication. Successful exploitation leads to partial impact to integrity.

Its EPSS score of 3.6% reflects a lower probability of exploitation activity in the wild over the next 30 days, placing it above 88% of all scored CVEs.

Check your external exposure to CVE-2011-4532

  • Confirm whether Siemens Automation License Manager is running on any internet-facing host or subdomain.
  • Match discovered service fingerprints against the version affected by CVE-2011-4532.
  • Prioritise remediation if the asset is public, business-critical, or near authentication/payment flows.

How ThreatPort helps with CVE-2011-4532

ThreatPort's external attack surface scanner checks your internet-facing assets — agentlessly, from the outside in — for the exposed services and versions that CVE-2011-4532 affects, then prioritises the finding by real risk using CISA KEV and FIRST.org EPSS.

Run a free external exposure scan

Are you exposed to CVE-2011-4532?

Run an instant, non-intrusive external scan to check your attack surface for CVE-2011-4532.

Start free scan

No credit card. Agentless.